#Profibus_DP ; ; This GSD-File must be used for all UNIGATE (module and IC) with Ident-Nr.3218H ; and Firmware V6.0 and higher. ; These Units support DPV0, DPV1 and Publisher-Support of DPV2 ; ; Historie: ; ========= ; V1.1 21.11.2003 La "Publisher_supp = 1" eingefügt ; V1.2 19.10.2006 La "Changed in Parameterdata" ; V1.3 19.02.2008 La "Ident_Maintenance_supp = 1" mit "GSD_Revision = 5" neu (alternativ) ; V1.4 23.06.2009 La 64 Wort I/O --> spez. Kennungsbyte --> konsistent ; V1.5 06.02.2015 La "(konsistent)" in Modul 7 ergänzt ; V1.6 12.07.2016 La "OrderNumber" entfällt ; V1.7 06.03.2018 La "GSD_Revision" auf 5 erhöht", "Ident_Maintenance_supp" ergänzt ; V1.8 15.12.2020 La C1_Max_Data_Len und C2_Max_Data_Len von 80 auf 240 geändert ; ; GSD_Revision = 5 Ident_Maintenance_supp = 1 ; Vendor_Name = "Deutschmann Automation GmbH" Model_Name = "UNIGATE IC - Profibus" Revision = "V1.7" Ident_Number = 0x3218 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "Revision H" Software_Release = "V6.0" ; 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 ; MaxTsdr_9.6 = 15 MaxTsdr_19.2 = 15 MaxTsdr_45.45 = 15 MaxTsdr_93.75 = 15 MaxTsdr_187.5 = 15 MaxTsdr_500 = 15 MaxTsdr_1.5M = 20 MaxTsdr_3M = 35 MaxTsdr_6M = 50 MaxTsdr_12M = 95 ; Redundancy = 0 Repeater_Ctrl_Sig = 2 24V_Pins = 0 Implementation_Type = "VPC3+B" Bitmap_Device = "DAGW" ; Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 1 Publisher_supp = 1 ;data transfer to other salves possible (DPV2-publisher) ; Modular_Station = 1 Max_Module = 16 Max_Input_Len = 244 Max_Output_Len = 244 Max_Data_Len = 488 Modul_Offset = 0 ; Fail_Safe = 0 Slave_Family = 9 Max_Diag_Data_Len = 11 ; DPV1_Slave = 1 C1_Read_Write_supp = 1 C1_Max_Data_Len = 240 ;UG-IC DPL only 64 Byte C1_Response_Timeout = 300 Max_Initiate_PDU_Length = 52 C2_Read_Write_supp = 1 C2_Max_Data_Len = 240 ;UG-IC DPL only 64 Byte C2_Response_Timeout = 300 C2_Read_Write_required = 1 C2_Max_Count_Channels = 2 ; DPV1_Data_Types = 0 ; Max_User_Prm_Data_Len = 237 ;depending from used Hardware (9..237) ; PrmText=1 Text(0)="disabled" Text(1)="enabled" EndPrmText ExtUserPrmData=1 "DPV1mode" Bit(7) 0 0-1 Prm_Text_Ref=1 EndExtUserPrmData Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x00 Ext_User_Prm_Data_Ref(0) = 1 ; ; Module = "1 Byte I/O (konsistent)" 0xB0 1 EndModule Module = "2 Byte I/O (konsistent)" 0xB1 2 EndModule Module = "4 Byte I/O (konsistent)" 0xB3 3 EndModule Module = "8 Byte I/O (konsistent)" 0xB7 4 EndModule Module = "16 Byte I/O (konsistent)" 0xBF 5 EndModule Module = "16 Worte I/O (konsistent)" 0xFF 6 EndModule Module = "32 Worte I/O (konsistent)" 0xFF,0xFF 7 EndModule ; Module = "64 Worte I/O (inkonsistent)" 0xFF,0xFF,0xFF,0xFF Module = "64 Worte I/O (konsistent)" 0xC0,0xFF,0xFF 8 EndModule Module = "122 Worte In" 0x5F,0x5F,0x5F,0x5F,0x5F,0x5F,0x5F,0x59 9 EndModule Module = "122 Worte Out" 0x6F,0x6F,0x6F,0x6F,0x6F,0x6F,0x6F,0x69 10 EndModule ; Module = "1 Byte Inp. 1 Byte Outp. (kons.)" 0x90,0xA0 11 EndModule Module = "8 Byte Inp. 8 Byte Outp. (kons.)" 0x97,0xA7 12 EndModule Module = "16 Byte Inp. 16 Byte Outp.(kons)" 0x9F,0xAF 13 EndModule Module = "16 Wort Inp. 16 Wort Outp.(kons)" 0xDF,0xEF 14 EndModule ;